An growing variety of vessels have encountered sudden port state points associated to sulfur emissions restrict exceedance attributable to inaccurate readings.
These false measurement readings are sometimes the results of poorly maintained exhaust fuel analyzers.
This technical information emphasizes the significance of calibration and upkeep routines, and monitoring gear efficiency.

Malfunctions of SOx scrubbers or exhaust fuel cleansing methods (EGCSs) that final multiple hour needs to be reported to the flag administration and the related port state administration. Nevertheless, generally a malfunction might go undetected as a result of the monitoring gear doesn’t register any improve in SO2 focus. Usually, the reason for false measurement readings is poor upkeep.

Since crew members should not specialists in SO2/CO2 emissions monitoring methods, they might battle to appropriately interpret measurement alerts and analyzer readings. The next DNV steering goals to reinforce understanding and construct confidence in making the precise choices when confronted with suspicious measurement outcomes.

Zero and detrimental SO2 measurement readings

Zero and detrimental SO2 readings don’t essentially point out a failure of the analyzer. Given the allowable calibration accuracy tolerance of +/-2% of the bottom measurement vary used, detrimental readings should still be thought-about inside the acceptable vary of the analyzer’s zero setting. Thus, additionally very low concentrations at in-service measurements could also be displayed as zero and even detrimental.

The next working situations sometimes help excessive scrubber cleansing efficiencies, leading to low SO2 ranges within the cleaned exhaust fuel:

Low sulphur content material of the gasoline used
Low engine load
Excessive wash water stream charges within the scrubber

Figuring out false readings

Regardless of the above, zero or detrimental readings should not at all times believable measurement outcomes. It’s extremely advisable to remain alert each time that is noticed. The best fault finder is the observer’s expertise, which permits a fast evaluation of whether or not the monitored state of affairs is life like.

As well as, any of the under observations is a robust indicator for inaccurate zero readings:

Irritating odour within the exhaust plume, generally with eye irritation
No or little or no fluctuations within the measurement readings even after adjusting the wash water stream; measurement readings might drop even additional into the detrimental vary after growing the wash water stream
CO2 readings under 5%

The usage of gasoline with a excessive sulphur content material also needs to end in noticeable SO2 concentrations within the cleaned fuel. Normally, the fuel analyzers carry out common self-checks which establish system malfunctions or irregularities. Nevertheless, you will need to ceaselessly test the system’s error messages.

Fault discovering

If the analyzer is suspected of displaying false readings, comply with the producer’s advisable corrective actions to establish any malfunctions.

When performing a leakage test, guarantee it covers your entire measuring system, together with the sampling probe and sampling line. Ingress air might considerably dilute the pattern and cut back SO2 concentrations to very low ranges.

Different systematic errors might happen in the course of the calibration course of. Potential pitfalls vary from deviations from the described process to the usage of calibration gases with part concentrations that differ from pre-settings within the analyzer’s calibration routine. Additionally, repeated pressured zero adjustment in the course of the zero-point setting with low SO2 readings can shift the zero reference over time, decreasing measurement sensitivity within the low focus ranges.

Recorded values can also differ from native show readings if the sensor sign shouldn’t be aligned with the required measurement vary setting within the management and monitoring system.

The removing of SO2 within the emissions monitoring system could also be attributable to the cooler. If measures to stop SO2 losses should not appropriately utilized, this can lead to false decrease readings.

Suggestions

At all times be alerted if zero or detrimental values happen over an extended interval, and carry out fast plausibility checks.
Carry out a easy validation check: improve the engine load and reduce the wash water stream. If the SO2 measurement sign doesn’t improve, the analyzer doubtless wants servicing.
Decrease analyzer malfunctions by strictly following the service, upkeep and calibration intervals and procedures.