Automatic Voltage Regulators (AVR) & Excitation

Reactive Power, Stability, and the Silent Path to Blackout

Introduction — voltage collapse happens before blackouts

When ships lose power, crews often focus on engines, breakers, or fuel. In many cases, the first failure occurred electrically, inside the excitation system — long before the blackout.

AVR and excitation failures are dangerous because:

  • they are poorly understood
  • symptoms are subtle
  • alarms are often ignored
  • recovery windows are short

What excitation actually does onboard ships

The excitation system:

  • controls rotor magnetic field
  • determines output voltage
  • supplies reactive power
  • stabilises parallel operation

Without excitation:

  • voltage collapses
  • motors stall
  • protection trips
  • PMS logic destabilises

The diesel engine can be running perfectly — and the ship still blacks out.


AVR operating modes — and why they matter

  • Voltage control — maintains terminal voltage
  • Reactive droop — enables load sharing
  • Excitation limiting — protects rotor from overheating
  • Manual mode — emergency operation only

ETO trap:
Manual AVR mode is often misunderstood as a “safe fallback”. In reality, it removes automatic stability control and increases blackout risk if used incorrectly.


🔧 Regulatory anchors (explicit)

IEC 60092-301

Requires:

  • stable voltage under varying load
  • excitation systems appropriate to generator design
  • protection against over-excitation

SOLAS Chapter II-1, Regulation 42

Voltage stability is implicit in the requirement to supply essential services.

A generator producing unstable voltage is not supplying power, even if frequency is correct.


🔻 Real-World Case: MV Dali — Reactive Power and Loss of Control (2024)

https://maritime-executive.com/media/images/article/Photos/Charts_Graphs/Dali-timeline-NTSB.png
https://againstthecurrent.org/files/FBI_Baltimore_MV_Dali.webp

In the MV Dali Baltimore incident, early reporting and expert commentary strongly suggest that electrical instability preceded total blackout.

While final reports are pending, the sequence highlights a known vulnerability:

  • reactive power demand spikes during manoeuvring
  • bow thrusters and auxiliaries load the system
  • excitation reaches limit
  • voltage collapses
  • protection trips generators
  • blackout occurs faster than recovery allows

This pattern has been documented repeatedly across the industry.


Excitation limits — the invisible wall

Generators have hard limits on:

  • field current
  • rotor temperature
  • magnetic saturation

When excitation hits its limit:

  • voltage drops suddenly
  • AVR cannot respond
  • motors draw more current
  • collapse accelerates

ETO judgement is recognising how close you are to that wall.


Why excitation problems cascade

Voltage drop causes:

  • motors to stall
  • current to increase
  • protection to trip
  • PMS to shed loads too late
  • generators to trip sequentially

By the time alarms escalate, the system may already be unrecoverable.


Knowledge to Carry Forward

AVR and excitation systems are not “fine-tuning devices”. They are stability governors.

Many ship blackouts begin not with fuel or engines, but with reactive power exhaustion. When excitation collapses, protection follows — and recovery time may be shorter than stopping distance.

If you don’t actively monitor excitation margins, you are already operating blind.